Slaughter 6330 6-in-1 3.5kV AC, 4kV DC MultiFunction Electrical Safety Tester

6330

New product

Slaughter 6330 MultiFunction Electrical Safety Tester. 3.5kV AC HiPot at 30mA, 4kV DC HiPot at 5mA, Insulation Resistance, 30Amp Ground Bond, Functional Run and Line Leakage.

More details

Call 1300 556 601 For Price

$10,442.86 tax excl.

More info



The 6330 is our most advanced multi-function electrical safety tester with 6-in-1 test capability. Our flagship model is designed to make advanced testing applications simple with the most intuitive user interface on the market.

With minimal setup time, you can perform AC Hipot, DC Hipot, Ground Bond, Insulation Resistance, Functional Run and Leakage Current tests on a variety of DUT’s.

The 6330 maximises production line throughput far beyond a single function tester, while taking up less space. Use the 6330 from the front panel or automate your testing via the standard RS-232 interface.


Common Applications

  • Medical
  • Appliance
  • Lighting
  • System Integration


The 6330 allows manufacturers to perform six of the most common electrical safety tests in a single instrument. This 6-in-1 Electrical Safety tester will perform AC Hipot, DC Hipot, Insulation Resistance, Ground Bond, Functional Run, and Line Leakage Tests in a single instrument. Equipped with the latest technology and features at a cost-effective price, the 6330 is a good solution for applications requiring multiple safety tests.

  • RS-232 Interface Option
  • Fully Adjustable Trip Ranges
  • 10 Memories, 20 Steps per Memory
  • Built-in Measuring Devices for LLT
  • Tamper Proof Front Panel Controls

 

 

 

Slaughter 6330 Front Panel

  1. RESET BUTTON: This is a momentary contact switch used to reset the instrument. If an out-of-range reading is detected during a test, the red failure lamp within the button will light. To reset the system for the next test, press and release this button. This button may also be used to abort a test in progress.
  2. TEST BUTTON: This is a momentary contact switch used to start a test. Press the green button to turn on the high voltage output when in test mode. The indicator lamp within the button will light when test expires with pass condition.
  3. LCD DISPLAY: The Liquid Crystal Display is the main readout for the operator and programmer of the test settings and test results.
  4. LOCK: This LED indicates that the Lock feature has been enabled.
  5. FAULT CONDITION INDICATORS: These LED’s indicate that the Neutral, Reverse, and Ground Line Conditions have been activated during a Line Leakage test.
  6. CURRENT OUTPUT TERMINAL: This terminal is used for the connection of the detachable 6-foot red high current test lead. This terminal is always used when performing a Ground Bond test.
  7. POWER SWITCH: Rocker-style switch with international ON ( | ) and OFF (0) markings.
  8. SET KEY: Use this key to advance forward through the setup menus.
  9. DOWN ARROW(∨): Use this key to decrease the numeric values in the setup mode. This key is also used to toggle ON/OFF functions. Also may be used to decrease output voltage during a test in 10-volt increments.
  10. UP ARROW(∧): Use this key to increase the numeric values in the setup mode. This key is also used to toggle ON/OFF functions. Also may be used to increase output voltage during a test in 10-volt increments.
  11. EXIT KEY: Use this key when you desire to enter the test mode to initiate a test. Also the key uses to enter the System menu parameters and to exit from the System menu.
  12. HIGH VOLTAGE OUTPUT TERMINAL: For the connection of the detachable 6-foot red high voltage test lead. The silicone rubber insulation is flexible for easy handling and is rated at 30KVDC. The terminal is recessed for safety when this lead is not being used.
  13. HIGH VOLTAGE ARROW (LED INDICATOR): This indicator flashes to warn the operator that high voltage is present at the high voltage output terminal.
  14. TERMINAL OUTPUT TERMINAL: For the connection of the detachable 6-foot black return test lead. This terminal is always used when performing a test.

Slaughter 6330 Back Panel

  1. EXTERNAL MD : Provides an access port for a custom measuring device. The port may be activated during Line Leakage testing from the instrument’s menu system. The operator must supply the appropriate measuring device as none is provided.
  2. FUSE RECEPTACLE: To change the fuse unplug the power (mains) cord and turn the fuse cap counter clockwise.
  3. CALIBRATION ENABLE KEY: To enter the calibration mode press this key while the instrument is being powered ON.
  4. SIGNAL INPUT: 9 pin D subminiature male connector for remote control of TEST, RESET, AND INTERLOCK functions as well as remote memory tests selection.
  5. SIGNAL OUTPUT: 9 pin D subminiature female connector for monitoring PASS, FAIL, and PROCESSING output relay signals.
  6. DUT POWER INPUT: Provides the line and neutral connections for an input power source to be used during Functional Run and Line Leakage testing. This input requires connection to a U.S. style single phase unbalanced power supply.
  7. DUT POWER OUTPUT: Provides the line and neutral connections from the 6330 to the DUT during Functional Run and Line Leakage testing. Provides the high voltage connections to the DUT during ACW, DCW and IR testing if the DUT OUTPUT and DUT-HV parameters are turned ON.
  8. GND CONNECTION: This terminal is wired in parallel with the Current Output terminal during a Ground Bond test and may be used in place of the front panel connection. During a Line Leakage test this connection provides a connection to one side of the measuring device (MD).
  9. CASE CONNECTION: This terminal is wired in parallel with the Return terminal during a Ground Bond test and may be used in place of the front panel connection. During a Line Leakage test this connection provides a connection to one side of the measuring device (MD). During ACW, DCW or IR testing this terminal provides the return connection.
  10. CHASSIS GROUND (EARTH) TERMINAL: This safety terminal should be connected to a good earth ground before operation.
  11. INPUT POWER RECEPTACLE: Standard IEC 320 connector for connection to a standard NEMA style line power (mains) cord.
  12. VOLTAGE SELECT SWITCH: Line voltage selection is set by the position of the switch. In the left position, it is set for 115-volt operation, in the right position it is set for 230-volt operation.
  13. TERMINAL FAN: To cool the instrument.